Kategorien

wireless-power

Product Brochure Wireless Power Transfer Coils of Würth Elektronik eiSos

Wireless Power Transfer Coils
Anfragen
Wireless Power Transfer Coils
2020
Transmitter Coils
Coil Arrays
Receiver Coils
Combi Coils
Wireless Power
Development Kit 200 W
Order Code 760 308 EMP, Version 1.0
Infineon and Würth Elektronik eiSos (WE) offer this wire -
less power development kit (order code 760308EMP) to
demonstrate the advantages of wireless power as well as to
give developers the opportunity to test and integrate a
wireless power solution into their application.
Key Specification
Mains power input voltage ............100 – 240 VAC
Regulated input voltage ....................24 VDC
Maximum transmitted power ...................200 W
Output voltage .........................19 – 20 V
Features
Plug & Play Wireless Power Development Kit
Complete solution consisting of TX and RX
Flexible and modular approach for fast integration of
wireless power into your product design
Data transfer between receiver and transmitter board
Manual and automatic output voltage control
IoT sensor I²C interface
Visit www.we-online.com/wirelesspower/200WKit for details
Strategic partnerships with all major chip set suppliers
Available at your Würth Elektronik
sales representative or online at:
www.we-online.com/wirelesspower/200Wkit
2019
www.we-online.com
Application Areas
of Wireless Power Transfer
Wireless Power
Transmission allows easy
and aseptic cleaning of
medical devices.
Hermetically sealed
housing is possible with
no contact degradation
by aggressive solvents.
Wireless Power
Transmission solves
problems in harsh, wet
and dirty environments
and increase the
reliability of the device.
Wireless Power
Transmission used in
furniture for charging
smart phones, tablets
and smart watches.
Wireless Power
Transmission enables
energy transfer for
different vehicles and
devices in the field of
eMobility.
Medical
Technology
Industry Furniture eMobility
WIRELESS POWER
* calculated with UDC = 20 V
Wireless Power Transmitter Coils,
Coil Arrays and Combi Coils
Electrical properties
Order Code L
(µH)
RDC max
(mΩ)
IRDC
(A)
Q SRF
(MHz)
Power
Capability (W)*
Size
(mm)
Compliance
Coils
760 308 101 24.0 100 6.0 90 6.0 < 100 53.3 x 53.3 x 6.0 Qi – A1
760 308 105 6.3 25 13.0 55 20.0 < 200 53.3 x 53.3 x 6.0 Qi – A5
760 308 110 24.0 100 6.0 180 5.0 < 100 53.3 x 53.3 x 6.0 Qi-A10; MP-A1/A7
760 308 100 110 24.0 100 6.0 180 5.0 < 100 Ø 50.0 x 6.0 Qi-A10; MP-A1/A7
760 308 111 6.3 25 13.0 80 20.0 < 200 53.3 x 53.3 x 6.0 Qi-A11; MP-A11
760 308 100 111 6.3 48 6.0 120 24.0 < 100 Ø 50.0 x 6.0 Qi-A11; MP-A11
760 308 104 113 12.0 72 8.0 120 16.0 < 150 59.5 x 52.0 x 4.0 Qi – A13
760 308 141 10.0 30 9.0 200 11.0 < 150 53.3 x 53.3 x 6.5 Qi – A29; MP-A5
760 308 100 141 10.0 30 9.0 180 11.0 < 150 Ø 50.0 x 6.7 Qi – A29; MP-A5
760 308 101 141 10.0 30 9.0 220 11.0 < 150 Ø 50.0 x 5.0 Qi – A29; MP-A5
760 308 103 102 10.0 55 7.0 130 11.0 < 150 53.3 x 53.3 x 4.5 Qi – MP-A2
760 308 103 146 8.5 56 8.0 140 11.0 < 100 55.0 x 47.0 x 4.5 Qi-MP-A8
760 308 102 142 5.8 12 18.0 100 12.0 < 300 53.3 x 53.3 x 6.5 works with Qi Tx IC’s
760 308 100 143 6.0 18 12.0 180 16.0 < 200 Ø 50.0 x 6.7 works with Qi Tx IC’s
760 308 102 144 19.5 45 9.5 220 5.0 < 200 53.3 x 53.3 x 7.0 works with Qi Tx IC’s
760 308 101 103 6.5 200 3.0 35 20.0 < 50 Ø 30.0 x 1.9 works with Qi Tx IC’s
760 308 101 104 6.8 125 2.5 42 20.0 < 50 Ø 20.5 x 2.8 works with Qi Tx IC’s
760 308 101 105 3.3 90 3.0 30 20.0 < 50 Ø 20.5 x 2.8 works with Qi Tx IC’s
760 308 101 106 2.5 90 2.5 30 38.0 < 50 Ø 20.0 x 2.8 works with Qi Tx IC’s
760 308 101 107 24.0 315 2.0 55 7.5 < 40 Ø 31.0 x 2.5 works with Qi Tx IC’s
760 308 103 109 10.2 50 9.0 130 11.0 < 150 57.0 x 51.0 x 4.2 Qi-MP-A9
760 308 101 302 5.3 35 8.0 100 27.0 < 100 Ø 50.0 x 4.7 works with Qi Tx IC’s
760 308 101 304 6.3 48 8.0 115 16.0 < 100 Ø 47.5 x 3.0 works with Qi Tx IC’s
760 308 102 308 3.0 35 8.5 60 27.0 < 150 50.0 x 30.0 x 2.4 works with Qi Tx IC’s
760 308 101 310 24.0 110 6.5 175 6.0 < 100 Ø 70.0 x 6.0 works with Qi Tx IC’s
760 308 101 311 5.8 14 21.0 220 13.0 < 400 Ø 70.0 x 8.5 works with Qi Tx IC’s
760 308 101 410 24.0 100 5.5 170 6.0 < 100 Ø 50.0 x 3.1 works with Qi Tx IC’s
760 308 101 411 6.3 48 7.5 110 20.0 < 150 Ø 50.0 x 2.8 works with Qi Tx IC’s
Coil Arrays
760 308 106 12.5-11.5-12.5 65 9.0 125 14.0 < 150 130.0 x 54.7 x 8.0 Qi-A6
760 308 103 113 12.5-11.5 -12-5 65 9.0 125 14.0 < 150 100.0 x 55.0 x 4.5 MP-A13
760 308 104 119 12.0-11.5 56 8.0 130 12.0 < 150 88.5 x 52.5 x 3.5 Qi-A19
760 308 104 120 6.9-6.4-6.9 45 9.0 100 15.0 < 150 91.7 x 50.0 x 5.5 Qi-A28
760 308 103 148 6.9-6.4 52 8.5 120 15.0 < 150 71.0 x 61.0 x 4.0 Qi-A28
760 308 103 145 11.3-11.3-11.3 83 8.5 150 10.0 < 150 109.0 x 56.0 x 5.2 Qi-MP-A6
760 308 103 147 8.5-7.5-8.5 56 9.0 145 11.0 < 150 100.0 x 55.0 x 5.2 Qi-MP-A8
760 308 103 149 10.2-9.8-10.2 55 9.0 135 8.0 < 150 106.0 x 57.0 x 4.2 Qi-MP-A9
Combi
Coils
760 308 101 150 6.3 / 1.2 48 / 55 7.5 / 7.0 85 / 82 27.0 / 48.0 < 100 / < 100 Ø 66.0 x 3.5 Qi – Airfuel Alliance – NFC
760 308 101 312 24.0 / 0.7 90 / 30 6.0 / 13.0 125 / 30 7.0 / 63.0 < 100 / < 200 Ø 54.0 x 4.0 Qi – Airfuel Alliance – NFC
* calculated with UDC = 20 V
Wireless Power Receiver
Coils and Combi Coils
Electrical properties
Order Code L
(µH)
RDC max
(mΩ)
IRDC
(A)
Q SRF
(MHz)
Power
Capability (W)*
Size
(mm)
Compliance
Coils
760 308 201 10.0 200 3.50 50 15.0 < 60 37.0 x 37.0 x 1.8 works with Qi Rx IC’s
760 308 103 202 12.0 200 3.00 33 13.0 < 50 48.0 x 32.0 x 0.96 works with Qi Rx IC’s
760 308 103 203 12.0 360 1.55 21 11.0 < 20 48.0 x 32.0 x 0.87 works with Qi Rx IC’s
760 308 103 204 16.7 430 2.00 32 11.0 < 30 38.5 x 30.5 x 0.83 works with Qi Rx IC’s
760 308 103 205 11.0 200 2.50 30 16.0 < 40 34.0 x 26.5 x 0.89 works with Qi Rx IC’s
760 308 103 206 7.5 380 1.55 16 23.0 < 20 28.0 x 15.0 x 0.76 Qi – Airfuel Alliance
760 308 102 207 8.0 80 5.00 30 16.0 < 80 40.0 x 40.0 x 1.2 works with Qi Rx IC’s
760 308 101 208 13.0 500 0.80 17 26.0 < 15 Ø 10.3 x 1.68 works with Qi Rx IC’s
760 308 101 208A
18.0 650 0.70 18 24.0 < 15 Ø 10.3 x 1.68 works with Qi Rx IC’s
760 308 102 210 7.5 180 3.00 45 22.0 < 50 37.0 x 37.0 x 1.8 Qi – Airfuel Alliance
760 308 103 211 7.3 200 2.50 28 12.7 < 40 46.0 x 36.0 x 0.5 Qi – Airfuel Alliance
760 308 102 212 5.4 240 2.00 18 25.0 < 30 29.0 x 29.0 x 0.64 works with Qi Rx IC’s
760 308 102 213 7.9 330 1.70 18 21.0 < 30 29.0 x 29.0 x 0.62 Qi – Airfuel Alliance
760 308 101 214 26.0 520 1.10 25 11.0 < 20 Ø 19.0 x 0.8 works with Qi Rx IC’s
760 308 105 214 6.3 350 1.50 15 25.0 < 20 Ø 19.0 x 0.8 works with Qi Rx IC’s
760 308 103 215 14.3 190 3.00 40 8.8 < 50 48.0 x 32.0 x 1.0 works with Qi Rx IC’s
760 308 101 216 7.2 440 0.80 10 32.0 < 5 Ø 6.0 x 2.0 works with Qi Rx IC’s
760 308 101 217 24.2 1400 0.40 13 17.5 < 5 Ø 10.3 x 1.86 works with Qi Rx IC’s
760 308 101 219 11.8 750 0.70 13 22.0 < 5 Ø 15.0 x 0.6 works with Qi Rx IC’s
760 308 101 220 12.6 340 1.10 20 19.0 < 20 Ø 17.0 x 0.82 works with Qi Rx IC’s
760 308 101 221 24.0 1150 0.40 16 10.0 < 5 Ø 6.0 x 4.31 works with Qi Rx IC’s
760 308 101 303 47.0 500 1.50 30 8.0 < 20 Ø 26.3 x 1.3 works with Qi Rx IC’s
760 308 101 309 10.0 450 1.50 20 19.0 < 20 Ø 26.3 x 0.5 works with Qi Rx IC’s
760 308 105 309 10.5 450 1.50 19 18.5 < 20 Ø 26.0 x 0.5 works with Qi Rx IC’s
Combi
Coils
760 308 103 305 8.8 / 1.4 220 / 100 2.6 / 5.0 30 / 47 22.0 / 16.0 < 40 / < 80 45.0 x 44.0 x 0.72 Qi – Airfuel Alliance – NFC
760 308 102 306 8.0 / 1.4 400 / 100 2.0 / 5.0 19 / 47
1 7. 5
/
19.0
< 40 / < 80 44.0 x 44.0 x 1.0 Qi – Airfuel Alliance – NFC
760 308 103 307 7.8 / 1.6 340 / 100 1.5 / 4.0 19 / 47 22.0 / 24.0 < 20 / < 40 40.0 x 27.0 x 1.0 Qi – Airfuel Alliance – NFC
more than you expect
www.we-online.com
Würth Elektronik eiSos differs from all other
component manufacturers in several aspects:
We guarantee all catalogue products
are available ex stock
Samples free of charge
Orders below MOQ
Design kits with lifelong free refill
Design Guide Trilogy of Magnetics, Trilogy of Connectors,
Abc of Capacitors, Abc of Power Modules & Application
Handbook The LTspice IV Simulator
Design Seminars and Webinars free of charge
Reference designs of leading IC manufacturers
Worldwide technical sales force and
field application engineers on site
DIE NECKARPRINZEN 99 9 9 2 1 0.0220.2’.DD