The information contained within is provided as a service to
our customers and for their information only. The information
and recommendations set forth herein are made in good faith
and are believed to be accurate at the date compiled. CorDEX
Instruments makes no warranty expressed or implied.
1. Chemical Product and Company Identification
Product Identification
EXIS Lithium-Ion Rechargeable Battery
Manufacturer
CorDEX Instruments Limited
Unit 1
Owens Road
Skippers Lane
Middlesbrough
TS6 6HE
2. Composition Information
*Lithium content : 0.66g
3. Hazards Identification
Primary routes of entry
Skin contact: NO
Skin absorption: NO
Eye contact: NO
Inhalation: NO
Ingestion: NO
Symptoms of exposure
Skin contact: No effect under routine handling and use.
Skin absorption: No effect under routine handling and use.
Eye contact: No effect under routine handling and use.
Inhalation: No effect under routine handling and use.
Reported as carcinogen: Not applicable
4. First Aid Measures
Inhalation: Not a health hazard.
Eye contact: Not a health hazard.
Skin contact: Not a health hazard.
Ingestion: If swallowed, obtain medical attention
immediately.
IF EXPOSURE TO INTERNAL MATERIALS WITHIN CELL DUE
TO DAMAGED OUTER CASING, THE FOLLOWING ACTIONS ARE
RECOMMENDED;
Inhalation
Leave area immediately and seek medical attention.
Eye contact
Rinse eyes with water for 15 minutes and seek medical
attention.
Skin contact
Wash area thoroughly with soap and water and seek
medical attention.
Ingestion
Drink milk/water and induce vomiting; seek medical
attention.
5. Fire Fighting Measures
General Hazard
Cell is not flammable. Combustion products include, but
are not limited to hydrogen fluoride, carbon monoxide and
carbon dioxide.
Extinguishing Media
Use extinguishing media suitable for the materials that are
burning.
Special Firefighting Instructions
If possible, remove cell(s) from fire fighting area. If heated
above 160°C, cell(s) may explode/vent.
Firefighting Equipment
Use NIOSH/MSHA approved full-face self-contained
breathing apparatus (SCBA) with full protective gear.
Hazardous Ingredients % CAS number
Aluminium Foil 2-10 7429-90-5
Metal Oxide
(proprietary)
20-50
Polyvinylidene
Fluoride (PVDF)
<5 24937-79-9
Copper Foil 2-10 7440-50-8
Carbon (proprietary) 10-30 7440-44-0
Electrolyte
(proprietary)
10-20
Stainless steel, nickel
and insert materials
Remainder N/A
Emergency Overview
May explode in a fire, which could release
hydrogen fluoride gas.
Use extinguishing media suitable for materials
burning in fire.
RUGGED AUTHORITY www.cord-ex.com